Tektronix TCP305A AC/DC Current Probe
-
Mã SKU: CAT-TEKTRONIX-TCP305ASKU: CAT-TEKTRONIX-TCP305A
-
Category: Current Probes.Category: Current Probes.
Liên hệ
The Tektronix TCP305A measures AC and DC current using a clamp-style sensor. Its specified bandwidth is DC to 50 MHz, with 50 A DC continuous current capability under the manufacturer’s operating conditions.
Tektronix TCP305A overview
The Tektronix TCP305A measures AC and DC current using a clamp-style sensor. Its specified bandwidth is DC to 50 MHz, with 50 A DC continuous current capability under the manufacturer’s operating conditions.
Product images

Specifications
| Manufacturer | Tektronix |
|---|---|
| Model | TCP305A |
| Measurement type | AC and DC |
| Bandwidth | DC to 50 MHz |
| Current capability | 50 A DC continuous |
| Connection / required interface | TCPA300 required |
| Required amplifier | TCPA300, separately specified; not assumed included |
| System DC accuracy | ±3% of reading |
| Probe construction | Split-core clamp |
| System qualification | Bandwidth and current specifications apply with the specified amplifier |
Current limits depend on frequency, pulse duration and operating conditions. Consult the manufacturer manual for derating and conductor-voltage ratings.
Measurement applications
This split-core probe measures current together with the TCPA300 amplifier. The amplifier provides the required probe drive and signal conditioning. Select the probe and range for the expected DC level and changing current; confirm pulse limits separately for transient measurements.
Connection schematic
Single insulated DUT conductor → TCP305A clamp TCP305A → TCPA300 amplifier (required) Amplifier output → correctly terminated oscilloscope input
Illustrative connection diagram, not an internal service circuit. De-energize the circuit before fitting or removing the probe where required by the manual. Check conductor insulation, voltage category, jaw closure and current limits. Clamp around one conductor for its individual current; enclosing both supply and return can cancel their magnetic fields.
Setup and compatibility
Specify the TCPA300 and compatible oscilloscope connection when requesting a complete system. Follow the amplifier manual for output termination and scaling. Degauss and zero the measurement system before use. The reference photo shows a family of probes and amplifiers; this listing is for the named probe.
Request a quotation in Vietnam
Request a quotation for Tektronix TCP305A. Include your oscilloscope model, current range, waveform frequency, conductor size and required accessories. Price, condition and local availability are confirmed individually.
Manufacturer references
Official Tektronix datasheet. Reviewed 19 October 2026.