Tektronix TICPMM10ET Extreme-Temperature MMCX Probe Tip

Stock:Còn hàng: / US origin

Liên hệ

Tektronix TICPMM10ET overview

The Tektronix TICPMM10ET is a 10X MMCX probe tip for the TICP IsoVu isolated current probe family. This ET variant supports the stated extended tip temperature range.

Product images

Tektronix TICPMM10ET manufacturer reference image 1
Manufacturer extreme-temperature tip family reference photograph. The label may show another attenuation variant; this listing is specifically for TICPMM10ET (10X).
Tektronix TICPMM10ET manufacturer reference image 2
Manufacturer TICP application reference photograph. The probe, oscilloscope and DUT illustrate use and are not assumed included with this accessory tip.

Specifications

Manufacturer Tektronix
Model TICPMM10ET
Product type Extreme-Temperature MMCX Probe Tip
Compatible probe family TICP025, TICP050, TICP100; confirm full connection configuration
Attenuation 10X
DUT connector MMCX
Differential input voltage range ±5 V
Offset range ±5 V; combined signal and offset limits apply
Maximum measurable input 6.5 V peak
Input impedance 500 Ω || <3 pF
Tip operating temperature −40 °C to +125 °C
Tip storage temperature −40 °C to +85 °C

Measurement applications

Connect the isolated probe to a suitable shunt or measurement point through the MMCX tip. Attenuation changes the probe input range and measurement sensitivity. Determine current from shunt voltage using the actual shunt resistance and the correct attenuation scaling.

Connection schematic

Current path → correctly rated shunt → load
Shunt sense output → TICPMM10ET MMCX tip (10X)
Tip → compatible TICP isolated probe → oscilloscope
Scale the result using attenuation and shunt resistance

Illustrative application connection schematic. Install accessories and connect the circuit according to the current Tektronix manual. Confirm ratings for the complete measurement path before use.

Setup and compatibility

Confirm the tip part number and full TICP connection arrangement before ordering. Differential signal and offset together must remain within the maximum measurable input. Temperature limits here apply to the tip; the probe body and oscilloscope have separate environmental limits.

Request a quotation in Vietnam

Request a quotation for Tektronix TICPMM10ET. Include the TICP probe model, shunt resistance, expected current and waveform, connection arrangement and temperature requirements. Price, condition and local availability are confirmed individually.

Manufacturer reference

Official Tektronix TICP system and accessory datasheet. Reviewed 21 October 2026. See the full document for test conditions, derating and configuration limits.

0902327669
0902327669
Messenger