Specifications, setup and FAQ
Rohde & Schwarz HMP2030 is a 3-channel DC power supply with up to 188 W total output. Three separately adjustable rails for a controller, analog circuitry and supporting electronics. Use this guide to compare its capabilities and prepare a rental, repair or purchase enquiry in Vietnam.

HMP2030 specifications at a glance
| Model | HMP2030 |
|---|---|
| Manufacturer | Rohde & Schwarz |
| Manufacturer order number | 3629.6718.03 |
| Output channels | 3 |
| Total output power | 188 W maximum |
| Voltage per channel | 0 V to 32 V |
| Maximum output current | 5 A per channel |
| Maximum channel power | 80 W per channel |
The 188 W total rating is shared across the instrument. Check both the per-channel limit and the combined load before enabling several outputs. Maximum voltage, current and power ratings do not apply simultaneously.
Choose the right HMP2030 configuration
Remote sensing helps compensate for voltage drops in the load leads. EasyArb supports programmed output patterns. Remote control requires the appropriate optional interface; confirm the installed module before planning automation.
Start with a list of the supply rails your device needs. Record the normal voltage, steady current and expected startup current for each rail. Then compare the combined demand with the available power. Leave room for the test conditions you intend to explore, instead of selecting a supply only from one headline rating.
For development work, independent channels can help separate power domains. For a production fixture, also consider connection time, repeatability and how the operator will save the result. If you need an automated sequence, check the actual interface, command support and software environment before committing to a setup.
Typical bench connection schematic
DC output (+) ── rated test lead ── DUT supply input (+) DC output (−) ── return lead ───── DUT supply return (−) Optional sense leads ──────────── DUT sense points
This is a functional connection guide, not an internal circuit diagram or a service schematic. DUT means device under test. Follow the manufacturer’s operating manual for terminal assignments, grounding, remote sensing and any series or parallel connection. Choose leads and fixtures suitable for the current and operating conditions.
Plan a repeatable bench test
- Define the voltage range, current limit and pass criteria before connecting the device.
- Check polarity and connections with the outputs disabled.
- Set the required protection levels for the device and the intended test.
- Enable the output using the documented procedure, then observe the voltage and current.
- Record settings, operating conditions and unexpected behavior with the test result.
Keep the instrument model and serial number with your records. Include the fixture, cable arrangement and firmware when these affect reproducibility. A result is easier to compare when the next engineer can recreate the same conditions. For formal verification, specify the required calibration evidence and measurement uncertainty in advance.
Rental, repair and purchase enquiries in Vietnam
For a HMP2030 rental enquiry, provide the project dates, delivery location, required interfaces and accessories. Describe the load and any startup or transient behavior that matters to the test. This helps the team assess whether the proposed configuration suits the work and confirm availability before a booking.
For purchase, request a quotation that identifies the exact model, condition, included accessories, warranty terms and calibration documents. For repair, describe the symptoms and any error messages. Avoid treating a quotation request as confirmation of stock, delivery or repair feasibility; these details depend on the specific equipment offered and the agreed scope.
Explore our Lost in HCM equipment and service enquiries. For technical reference, consult the official Rohde & Schwarz HMP2000 product information. The manufacturer’s manual and applicable specifications govern operation.
HMP2030 FAQ
How many outputs does the HMP2030 have?
The HMP2030 has 3 output channels, each adjustable from 0 V to 32 V. The instrument has a maximum combined output power of 188 W.
Can the HMP2030 deliver maximum voltage and current together?
No. The output must remain within its power limits: 80 W per channel, with 188 W total for the instrument. Calculate voltage multiplied by current for each intended load.
Can I request a HMP2030 rental in Vietnam?
Send the required dates, delivery location, channel requirements and documentation needs to Lost in HCM. Rental availability and the supplied configuration must be confirmed in a quotation.
What should I provide for a HMP2030 repair enquiry?
Provide the serial number, fault description, error messages and photographs. Repair feasibility, parts, cost and turnaround are confirmed after assessment.
What is the manufacturer order number for HMP2030?
The manufacturer lists order number 3629.6718.03. Optional interfaces, rack accessories and other additions must be specified separately.