Tektronix TIVP1 overview

The Tektronix TIVP1 is an IsoVu isolated voltage probe with 1 GHz bandwidth and a 2 m fiber cable. Select the sensor tip for the actual differential voltage and circuit connection.

Product images

Tektronix TIVP1 manufacturer reference image 1
Manufacturer IsoVu TIVP series reference photograph. The photo may show a related bandwidth or cable-length version; this listing is for TIVP1 with 2 m fiber cable.
Tektronix TIVP1 manufacturer reference image 2
Manufacturer application photograph showing an IsoVu measurement setup. Oscilloscope, circuit board and supporting equipment illustrate use and are not assumed included.

Specifications

Manufacturer Tektronix
Model TIVP1
Product type IsoVu Isolated Voltage Probe
Bandwidth 1 GHz
Fiber cable length 2 m
Measurement architecture Optically isolated differential voltage measurement
Oscilloscope interface TekVPI; verify instrument and firmware compatibility
Differential input capability Tip-dependent: ±5 V to ±2500 V across supported configurations
Maximum stated family common-mode voltage Up to ±60 kV under manufacturer conditions; apply frequency and safety derating
Standard tip configuration reference Manufacturer listings identify TIVPMX10X; verify supplied kit and tip ratings

Measurement applications

Use an isolated measurement path to investigate switching waveforms when the signal reference moves relative to earth. Specify both the signal swing and the reference-node behavior when selecting the system. The fiber length helps define how the sensing head and oscilloscope can be positioned in the test setup.

Connection schematic

DUT node + ── rated sensor tip input + ┐
                                     ├── isolated sensor head
DUT node − ── rated sensor tip input − ┘
Sensor head ── 2 m optical fiber ── TIVP1 interface / controller
Interface / controller ── compatible TekVPI oscilloscope

Illustrative application connection schematic. Follow the current manufacturer instructions for accessory installation and circuit grounding. Check the rating of every component in the measurement path before energizing the circuit.

Setup and compatibility

Confirm the probe, sensor tip cable, connector, oscilloscope and firmware as one complete system. The ±2500 V figure describes a supported high-attenuation configuration and is not the range of every tip. Check differential input range, offset, common-mode limits and frequency derating for the selected tip in the current Tektronix manual.

Request a quotation in Vietnam

Request a quotation for Tektronix TIVP1. Include the oscilloscope model, signal bandwidth, differential and common-mode voltage, connection geometry and required accessories. Price, condition and local availability are confirmed individually.

Manufacturer references

Official Tektronix product specifications. Reviewed 21 October 2026. Consult the complete data sheet and manual for test conditions and configuration-dependent limits.