Tektronix TRCP0600 AC Rogowski Current Probe
-
Mã SKU: CAT-TEKTRONIX-TRCP0600SKU: CAT-TEKTRONIX-TRCP0600
-
Category: Current Probes.Category: Current Probes.
Liên hệ
The Tektronix TRCP0600 measures AC current with a flexible Rogowski sensing loop. Its specified bandwidth is 12 Hz to 30 MHz, with 600 A peak current capability under the manufacturer’s operating conditions.
Tektronix TRCP0600 overview
The Tektronix TRCP0600 measures AC current with a flexible Rogowski sensing loop. Its specified bandwidth is 12 Hz to 30 MHz, with 600 A peak current capability under the manufacturer’s operating conditions.
Product images

Specifications
| Manufacturer | Tektronix |
|---|---|
| Model | TRCP0600 |
| Measurement type | AC only; does not measure DC |
| Bandwidth | 12 Hz to 30 MHz |
| Current capability | 600 A peak |
| Connection / required interface | 1 MΩ BNC |
| Sensitivity | 10 mV/A |
| Minimum current | 500 mA |
| Coil cross-section diameter | 4.5 mm |
| Typical accuracy | ±2% of reading |
| Oscilloscope termination | 1 MΩ |
Current limits depend on frequency, pulse duration and operating conditions. Consult the manufacturer manual for derating and conductor-voltage ratings.
Measurement applications
The flexible Rogowski loop can be positioned around a single conductor to observe changing current. It is useful for AC waveforms in power-conversion and motor-drive development. It cannot report a steady DC component. Position and close the coil as instructed in the manual, and use the stated output sensitivity when scaling the oscilloscope.
Connection schematic
Single insulated DUT conductor → closed TRCP0600 sensing loop Loop → probe electronics → oscilloscope BNC input (1 MΩ) Probe power → specified supply
Illustrative connection diagram, not an internal service circuit. De-energize the circuit before fitting or removing the probe where required by the manual. Check conductor insulation, voltage category, jaw closure and current limits. Clamp around one conductor for its individual current; enclosing both supply and return can cancel their magnetic fields.
Setup and compatibility
Connect the probe electronics to a compatible 1 MΩ BNC input. Confirm the power arrangement, coil geometry and frequency range for the application. Peak current is not a continuous RMS rating.
Request a quotation in Vietnam
Request a quotation for Tektronix TRCP0600. Include your oscilloscope model, current range, waveform frequency, conductor size and required accessories. Price, condition and local availability are confirmed individually.
Manufacturer references
Official Tektronix datasheet. Reviewed 19 October 2026.