Tektronix TICS0005 Wideband Current Shunt

Stock:Còn hàng: / US origin

Liên hệ

Tektronix TICS0005 overview

The Tektronix TICS0005 is a 5 mΩ wideband current shunt for a compatible TICP IsoVu current measurement setup. This listing is for one shunt, rather than a multipack.

Product images

Tektronix TICS0005 manufacturer reference image 1
Manufacturer TICS family photograph showing four resistance variants. This listing is for one TICS0005 (5 mΩ) shunt only.
Tektronix TICS0005 manufacturer reference image 2
Manufacturer TICP application reference photograph. The oscilloscope, isolated probe and DUT illustrate the measurement system and are not assumed included with this shunt.

Specifications

Manufacturer Tektronix
Model TICS0005
Product type Wideband Current Shunt
Compatible probe family TICP025, TICP050, TICP100; confirm full connection configuration
Resistance 5 mΩ
Bandwidth, typical 250 MHz
Rise time, typical 1.6 ns
Maximum DC current 12 A
Maximum pulse current 200 A; duration and waveform derating applies
Manufacturer dynamic range ±100 A
DC gain accuracy <2%
Operating temperature −40 °C to +85 °C
Built-in fuse interruptible voltage limit 400 V; see manufacturer conditions

Measurement applications

Measure current by observing the differential voltage developed across the known shunt resistance. Select resistance for the expected current and acceptable circuit insertion loss. The probe, shunt and interconnect together determine the usable measurement bandwidth and current range.

Connection schematic

Circuit current → TICS0005 (5 mΩ) → load
Shunt sense terminals → compatible shunt cable / tip → TICP isolated probe
TICP probe → compatible oscilloscope
Measured current I = measured shunt voltage / shunt resistance

Illustrative application connection schematic. Install accessories and connect the circuit according to the current Tektronix manual. Confirm ratings for the complete measurement path before use.

Setup and compatibility

Verify shunt power dissipation and the manufacturer pulse-current curve for the actual pulse width and waveform. A peak pulse value does not extend the continuous DC rating. The built-in fuse has a maximum interruptible voltage of 400 V; follow the full manufacturer installation and protection requirements.

Request a quotation in Vietnam

Request a quotation for Tektronix TICS0005. Include the TICP probe model, shunt resistance, expected current and waveform, connection arrangement and temperature requirements. Price, condition and local availability are confirmed individually.

Manufacturer reference

Official Tektronix TICP system and accessory datasheet. Reviewed 21 October 2026. See the full document for test conditions, derating and configuration limits.