Features
• 20″ calibration arm, 1/2 and 3/8″ square drive
• Use to calibrate any TTC series transducer
• Arms are certified to manufacturer’s standards
Liên hệ
The transducer calibration fixture TTC1530 is a Snap-on transducer calibration fixture that Lost in HCM supplies to workshops and factories across Vietnam. It uses a 3/8 in square drive, so match sockets and adapters to that size. Snap-on lists the country of origin as USA.

Plants that run their own torque test benches need a way to confirm their transducers between full lab visits. The transducer calibration fixture TTC1530 supports that check on site. So the team can catch a drifting sensor before it passes bad wrenches.
The 20 inch arm fits 1/2 and 3/8 inch square drives, while the 40 inch arm uses a 1-1/4 inch square drive. Every item lists a field repairable warranty. Lost in HCM supplies these fixtures to FDI plants with CO/CQ papers and a VAT e-invoice.
These figures come from the Snap-on listing for TTC1530. Values marked “calculated” are unit conversions we added for convenience.
| Snap-on part number (SKU) | TTC1530 |
|---|---|
| Country Of Origin | USA |
| Warranty | Field Repairable, See Repair Part Warranty, Repair in the Field, The item will be Audited at the Replacement Processing Center. |
Dead-weight calibration uses a simple rule: torque equals force times distance. First, you mount the transducer so it cannot turn and fit the arm or wheel to its drive. Next, you hang a certified weight at the marked point, and the weight creates a known torque.
Then you compare the readout with the expected value at several points across the range. For example, a lab may load 20, 60, and 100 percent of full scale. Finally, the team records each error and decides whether the transducer passes.

The details below explain how the wheels and arms cover low and high ranges. They also show what to check before you add a fixture to your TTC test bench.
Snap-on also lists these details for TTC1530:
A calibration fixture earns its place where a team must confirm a transducer without sending it away. The tasks below are the most common uses we see from buyers in Vietnam.

Calibration wheels and arms matter wherever a plant runs its own torque test bench. The industries below rely on them to keep their transducers honest. Many of these teams work in FDI plants across Vietnam.
Before you buy, compare the transducer calibration fixture TTC1530 with other dead-weight options on the points that matter. However, the arm alone is only part of the decision. Instead, buyers should check fit with their transducers and the weights and certificates they need.
| Brand | Comparable product | Strength | Consider |
|---|---|---|---|
| Snap-on | transducer calibration fixture TTC1530 | Tight Snap-on tolerances and a broad matching range. | Lead time depends on import stock. |
| Norbar | Norbar calibration beams and weights | Dead-weight approach from a UK maker well known in torque labs | Built around Norbar transducers, so check fittings for TTC units |
| Stahlwille | Stahlwille torque calibration systems | Complete calibration benches for workshop and lab use | A full system is a larger step than a single arm |
| Tohnichi | Tohnichi torque calibration equipment | Common in Japanese-owned plants that standardize on Tohnichi tools | Confirm that drive fittings match the transducers you already own |
| CDI Torque Products | CDI torque tester accessories | CDI is a Snap-on company with a long torque tool history | Check which accessories fit TTC transducers before you order |
Choose a fixture by the range of your transducers first, then by drive size. This family covers in-oz wheels up to a 40 inch arm. Meanwhile, labs that need a full bench may look at complete systems, so confirm current specs with each maker. Specifications change over time, so confirm current data with each maker before you decide.
For other sizes in the same range, compare 5" Calibration Wheel (max 150 in-lb) – TTC1510, 10" Butterfly Wheel (max 250 ft-lb) – TTC1520, 1-1/4" Drive 40" Calibration Arm – TTC1540, 2-1/2" Calibration Wheel (max 50 in-oz) – TTC500. Also browse the full Snap-on torque tools shop for handles, testers and adapters.

What are the main specifications of TTC1530?
It uses a 3/8 in square drive, so match sockets and adapters to that size. Snap-on lists the country of origin as USA.
Can I buy the transducer calibration fixture TTC1530 in Vietnam?
Yes. Lost in HCM sources the transducer calibration fixture TTC1530 from Snap-on for companies in Vietnam. We quote it with CO/CQ papers and a VAT e-invoice, then deliver nationwide.
What is a calibration arm used for?
A calibration arm applies a known torque to a transducer, using a weight at a fixed distance. Then you compare the transducer reading with the expected value. As a result, you can see whether the transducer still reads true.
Are weights included with these fixtures?
The product data does not list weights as part of these items. Therefore, plan to buy certified weights separately. Ask us when you request a quote, and we will help you match weights to the fixture.
When should I use a wheel instead of an arm?
Wheels suit lower ranges, from 50 in-oz on the small wheel to 250 ft-lb on the butterfly wheel. Arms suit higher loads, because their long levers multiply the weight. In short, the transducer range decides the choice.
Send us the part number, quantity and delivery site, and we will reply with a quote. You can request a quote online or call 0902 327 669.
• 20″ calibration arm, 1/2 and 3/8″ square drive
• Use to calibrate any TTC series transducer
• Arms are certified to manufacturer’s standards
| Country Of Origin | USA |
Field Repairable, See Repair Part Warranty, Repair in the Field, The item will be Audited at the Replacement Processing Center.